com Test Source: they really
are all necessary and useful.
The desired measurement
was taken with the following
parameters:
- Start frequency: 950 MHz
- End frequency: 2150MHz
- Frequency step: 1 MHz
- Time interval per step:
500 ms
- Signal level: -35 dBm
These values allowed the
analysis of the entire satel-
lite frequency range and the
fluctuations in the directly
connected analyzer turned
out to be approximately +/-
3 dBm.
Since the WORK Micro-
wave Handheld Satcom Test